The L-type of Inter-Connectors are used for connecting
PCB's to tracks on LCD's that are on the same side as the viewing side of the LCD; on the top of the glass. L-type of Inter-Connectors are particularly suitable for connecting PCB's to dot-matrix LCD's.
All L-type of Inter-Connectors are custom made to order using specially designed tools. The dimensions given below are for a typical shape.
Outline Dimensions:
![]() |
![]() |
|
|
L-type
|
|
Application
|
Dimensions and Tolerances:
|
|
|
Unit
|
0.05P
|
0.01P | 0.18P | 0.25P |
|
Pitch
|
P
|
mm
|
0.05 +0.03/-0.01
|
0.10 ± 0.05 | 0.18 ± 0.05 | 0.25 ± 0.05 |
| Colour | blue/white | white | ||||
|
Length
|
L
|
mm
|
5.0 ~ 90.0 ± 0.65%
90.1 ~ 150.0 ± 0.6 150.1 ~ 200.0 ± 1.0 200.1 ~ 275.0 ± 1.5 |
|||
|
Height
|
H
H1 (H≤8.0)
H1 (H>8.0) H2 H3 |
mm
|
4.1 ~ 10.0 ± 0.2 10.1 ~ 15.5 ± 0.6
1.5 ~ 5.2 ± 0.2 ≥ 5.3 ± 0.25 0.7 / 1.1 / 1.2 - typical 1.1 1.1 ~ 5.0 ± 0.1 - typical 1.7 |
|||
|
Width
|
W
W1 W2 |
mm
|
3.0 ~ 6.0 ± 0.2 - preferable 4.0
≥ 1.0 ± 0.2 1.0 ~ 3.0 ± 0.15 |
|||
|
Width conductive core
|
Z
|
mm
|
0.7 ± 0.05
|
0.5 ± 0.05 | ||
Basic Properties:
|
|
|
Unit
|
|
0.10P/0.18P/0.25P |
|
Specific gravity
|
Isolator
Conductor Side isolation |
|
1.15
1.15 1.05 |
|
|
Shore hardness A
|
Isolator
Conductor Side isolation |
ISO7619A
|
65 ~ 73
60 ~ 65 40 ~ 50 |
65 ~ 73
63 ~ 67 40 ~ 50 |
|
Compression set *
|
|
%
|
15 ~ 20
|
|
|
Volume resistance
|
Isolator
Conductor Side isolation |
Ω.m
|
1.0•1012
1.0•109 |
1.0•1012
3.0•10-2 ~ 6.0•10-2
8.0•1011 |
|
Dielectric breakdown voltage
|
Isolator
Support |
V/m
|
23•106 ~ 27•106
23•106 ~ 27•106 |
|
|
Isolation resistance (500V DC) *
|
Ω |
> 1.0•109
|
||
|
Operating temperature range
|
|
°C
|
-25 ~ 85
|
|
* Tests carried out with Shin-Etsu standard methods.
Note:
Shin-Etsu Inter-Connector has been registered in the European Community, TM No. 000299016, and in the United States of America, TM No. 2078941.
Every item or numerical value indicated herein is measured by Shin-Etsu and out of guarantee.
Compression curves are for reference only. Actual resistances and compression forces are up to the design of substrates and holder constructions. More information can be found in the design guides.
The quality of the assembled Inter-Connector is out of guarantee.
Please make sure to review the purpose and conditions of use and practice you own tests.
Industrial ownership like patent doesn't guarantee the usage of the Inter-Connector.